Tunnel Portal Construction
Tunnel portal areas may require retaining structures to support approach excavations and manage ground conditions around the tunnel entrance.

Deep Excavation & Retaining Wall Specialists
Jalmala Boring Works specializes in Diaphragm Wall Construction for deep excavations, basements, metro projects, commercial developments, and industrial infrastructure. We execute complete diaphragm wall work from 400 mm to 1200 mm thickness and depths of up to 40 metres, delivering watertight, high-strength retaining walls with minimal ground movement. Our end-to-end solution includes guide wall construction, slurry-supported panel excavation, reinforcement cage installation, tremie concreting, water-stop systems, and quality-controlled execution.
A step-by-step overview of how Jalmala Boring Works constructs high-quality Diaphragm Walls — from guide wall installation to final panel completion — with precision, safety, and six decades of expertise.







Detailed survey, panel marking, and guide wall construction for accurate alignment.

Preparation of slurry and excavation of diaphragm wall panels.

Formation of watertight joints and cleaning of excavated trench.

Fabrication and placement of reinforcement cage into trench.

Continuous concrete placement using tremie pipes.

Final wall formation, testing, and quality assurance activities.






Tunnel Infrastructure & Underground Construction
Specialist diaphragm wall and ground-support solutions for tunnel portals, underground access structures, deep excavation and cut-and-cover construction. Jalmala Boring Works brings specialist foundation engineering experience to complex underground infrastructure requirements.
Tunnel construction is an important part of transportation, railway, metro, highway and underground infrastructure development. These projects often require specialised engineering solutions for tunnel portals, approach structures, underground access shafts and cut-and-cover sections. Depending on the ground profile and construction method, excavation support systems are required to maintain stability and protect surrounding infrastructure.
Diaphragm walls are reinforced concrete retaining structures constructed below ground level in individual panels. They can be used in selected tunnel-related applications where deep excavation support, ground retention and controlled underground construction are required. Their design depends on soil conditions, groundwater levels, excavation depth, structural loads and the requirements of the overall tunnel project.
Jalmala Boring Works is a family-owned, third-generation foundation contractor established in 1962. The company specialises in pile foundations, diaphragm walls and ground anchoring. With experience in specialist foundation and ground-engineering operations, the company can discuss technical requirements for underground and infrastructure construction projects.
As a tunnel diaphragm wall contractor in India, Jalmala Boring Works focuses on specialist foundation activities that may be required for tunnel portals, shafts, underground structures and deep excavation support.
Diaphragm wall systems may be considered for different underground construction applications. The appropriate arrangement is determined by the project's engineering design, site investigation and construction sequence.
Tunnel portal areas may require retaining structures to support approach excavations and manage ground conditions around the tunnel entrance.
Vertical access shafts may use diaphragm walls as part of a designed retaining system for excavation, equipment access and underground connections.
Diaphragm walls can form the perimeter support for selected cut-and-cover tunnel structures constructed through staged excavation.
Some tunnelling methods require launching shafts where ground retention, excavation depth and working space must be addressed through engineered support.
Receiving shafts may require underground retaining structures designed around equipment recovery, excavation stability and project-specific construction requirements.
Connecting chambers and underground infrastructure structures may require diaphragm walls depending on their geometry and ground-support requirements.
The use of diaphragm walls is not limited to one tunnel construction method. Their suitability must be assessed against the tunnel alignment, excavation arrangement, groundwater conditions and the structural design. A specialist diaphragm wall contractor for tunnel construction should work according to the approved drawings and method statement.
Diaphragm wall construction generally follows a panel-based sequence. The exact process depends on the project design, ground conditions, equipment and technical specifications. Typical construction activities include:
The working area is prepared and the wall alignment is established using approved project drawings. Site access, underground utilities, working platforms and nearby structures are considered before excavation begins.
Guide walls are constructed along the diaphragm wall alignment. They help maintain the required excavation position and provide guidance for the excavation equipment.
The trench is excavated panel by panel using suitable diaphragm wall equipment such as a hydraulic grab or trench cutter. Excavation depth and panel geometry follow the approved design.
Bentonite or another approved support fluid may be used to stabilise the excavated trench. Slurry properties, level and cleanliness are checked according to project requirements.
The designed reinforcement cage is lifted and positioned inside the excavated panel. Cage dimensions, cover, embedded items and positioning are checked against approved drawings.
Concrete is placed through tremie pipes using an approved procedure. The concrete displaces the support slurry, which may be recovered and processed for reuse where permitted.
Panel joints and construction records are checked according to the specified quality requirements. Adjacent panels are constructed in the approved sequence to achieve the designed wall arrangement.
Engineering and Construction Quality
Tunnel-related excavation can take place near existing roads, buildings, utilities and other infrastructure. Diaphragm wall construction must therefore be coordinated with the overall tunnel design, ground investigation, excavation sequence and site safety requirements.
Soil layers, rock profile, groundwater levels and ground properties influence the design and construction methodology for diaphragm walls.
Correct positioning and verticality are important for panel geometry, wall continuity and compatibility with adjoining underground structures.
Groundwater conditions influence excavation support, slurry management, wall design and construction-stage controls.
Joint arrangements and sealing details must follow the approved design, particularly where groundwater control and structural continuity are important.
Reinforcement cage positioning, concrete properties and tremie placement require suitable inspection and documentation.
Existing structures, roads and utilities may require monitoring and protective measures according to project risk assessments and approved plans.
Tunnel infrastructure projects can require several specialist foundation and ground-support activities. Depending on the project design, these may include deep foundation systems, retaining walls and anchoring arrangements. Coordination between these activities is important for construction sequencing and overall structural performance.
Jalmala Boring Works specialises in three core service areas: pile foundations, diaphragm wall construction and ground anchoring. These services address different engineering requirements and may be considered individually or as part of a coordinated foundation package where the project scope requires them.
Pile foundations transfer structural loads to suitable deeper soil or rock layers. They may be used for tunnel-related buildings, approach structures, equipment facilities and other infrastructure components where deep foundation support is required.
Diaphragm walls provide underground retaining support for selected deep excavations and below-ground structures. Their design may include consideration of panel geometry, joints, groundwater and structural connections.
Ground anchors may provide additional restraint to retaining structures where permitted by design and site conditions. Their arrangement depends on anchor capacity, ground profile, adjacent property boundaries and the approved excavation support system.
These specialist capabilities allow the company to discuss different underground construction requirements with infrastructure developers, EPC contractors and project consultants seeking a tunnel diaphragm wall contractor in India.
Jalmala Boring Works is a family-owned, third-generation foundation contractor with a history dating back to 1962. Based in Ahmedabad, Gujarat, the company provides specialist piling, diaphragm wall and ground anchoring services for infrastructure, industrial, commercial and residential developments.
The company operates modern SANY hydraulic piling and diaphragm wall rigs. Equipment selection is planned around project requirements, ground conditions, site access, working platform availability and the approved construction methodology.
Jalmala Boring Works follows ISO 9001:2015 certified processes and gives importance to construction planning, equipment management, operational coordination and site safety. Appropriate bentonite management and excavation stability procedures are important considerations during diaphragm wall operations.
With more than six decades of industry experience and operations across 20+ Indian states, Jalmala Boring Works can discuss specialist foundation requirements with infrastructure companies, contractors, engineering consultants and project developers.
For a tunnel-related diaphragm wall enquiry, useful preliminary information includes project location, tunnel alignment drawings, excavation depth, geotechnical investigation report, proposed panel dimensions and construction schedule. These details help establish the technical scope for further discussion.
1962
Established
60+
Years of Experience
20+
Indian States Served
3
Core Specialist Services
Tunnel and underground infrastructure development across India requires specialist construction methods suited to different geological conditions and project environments. Tunnel portals, access shafts and underground structures may involve deep excavation and retaining systems designed to manage surrounding ground conditions.
Jalmala Boring Works is based in Ahmedabad, Gujarat, and undertakes specialist foundation and ground-engineering work across India, subject to project scope and operational requirements. The company can discuss diaphragm wall and foundation requirements with clients and contractors working on infrastructure developments in Gujarat and other Indian states.
Project-specific considerations include soil profile, groundwater, excavation geometry, surrounding infrastructure, equipment access and construction sequence. These factors should be evaluated by the project engineering team before finalising the retaining system and construction methodology.
If your project requires a tunnel diaphragm wall construction contractor, contact Jalmala Boring Works to discuss the proposed work package and relevant technical requirements.
A diaphragm wall is a reinforced concrete wall constructed underground in individual panels. In suitable tunnel-related projects, it can provide retaining support around tunnel portals, access shafts, underground station structures and cut-and-cover sections.
Diaphragm walls may be used for tunnel approach structures, portal excavations, launch and receiving shafts, underground access structures and cut-and-cover tunnel sections. Their application depends on the tunnel design, ground conditions and construction methodology.
A diaphragm wall can retain surrounding soil and form part of an engineered excavation-support system. Depending on the design, it may work with slabs, struts, ground anchors or other structural support arrangements during excavation.
Depending on ground conditions and project specifications, diaphragm wall construction may use hydraulic grabs, trench cutters, crawler cranes, slurry mixing and desanding equipment, reinforcement cage lifting equipment and concrete tremie systems.
Important checks include panel alignment, excavation depth, trench verticality, slurry properties, sediment removal, reinforcement cage positioning, concrete quality, tremie placement and panel joint requirements. The approved project specifications determine the inspection and testing procedures.
Jalmala Boring Works is based in Ahmedabad, Gujarat, and undertakes specialist foundation and ground-engineering work across India, subject to project scope, technical requirements and operational planning.
You can contact Jalmala Boring Works at +91 93745 45415 or jalmala.pile@gmail.com. Share the project location, tunnel drawings, geotechnical report, excavation depth and proposed construction requirements for an initial discussion.
Discuss Your Tunnel Project
Contact Jalmala Boring Works for a discussion about diaphragm wall construction, pile foundations and ground anchoring for tunnel portals and underground infrastructure projects.
Contact Person: Mr. Amrulla Memon
Phone: +91 93745 45415
Email: jalmala.pile@gmail.com
Address: Dholka Road, Near Nariampura Village, Narimanpura, Sarkhej-Okaf, Ahmedabad, Gujarat 382210, India